Search results for "Quadrupole mass analyzer"
showing 10 items of 22 documents
Quadrupole excitation of stored ion motion at the true cyclotron frequency
1995
Abstract The motion of an ion in a Penning trap has been investigated in the presence of an azimuthal quadrupole radio frequency field and a damping force provided by buffer gas collisions. Analytical expressions are derived which describe the line shape of the cyclotron resonance as well as the properties of the mass-selective cooling mechanism for heavy ions. Excellent agreement is observed between theoretical results and experimental data obtained with the tandem Penning trap mass spectromer ISOLTRAP at ISOLDE (CERN).
Properties and performance of a quadrupole mass filter used for resonance ionization mass spectrometry
1998
Abstract The performance of commercial quadrupole mass spectrometers (QMS) with a number of imperfections, as compared to the ideal hyperbolic geometry, has been characterized using the computer simulation program simion 3d version 6.0. The analysis of simulated QMS geometries focuses primarily on modeling of the internal potential, the study of field deviations, and the influence of finite length on performance of the QMS. The computer simulation of ion trajectories in the QMS field yields predictions for optimum working conditions and provides estimates for the resolving power and the maximum isotopic abundance sensitivity. Experimental measurements that confirm these expectations are pre…
Determination of fungicide residues in fruits and vegetables by liquid chromatography–atmospheric pressure chemical ionization mass spectrometry
2002
Abstract A liquid chromatography (LC) method for the quantitative determination of five fungicide residues (dichloran, flutriafol, o -phenylphenol, prochloraz and tolclofos methyl) in oranges, lemons, bananas, peppers, chards and onions is described. The residues were extracted by matrix solid-phase dispersion (MSPD) using C 8 . Quantitative analysis was performed by isocratic LC coupled to quadrupole mass spectrometer using atmospheric pressure chemical ionization in the negative ionization mode. The limit of quantification was 0.01 mg kg −1 for flutriafol, o -phenylphenol and dichloran, and 0.1 mg kg −1 for prochloraz and tolclofos methyl. The MSPD method is also suitable for LC–UV analys…
Time-resolved X-ray powder diffraction on a three-way catalyst at the GILDA beamline
2003
Time-resolved X-ray diffraction experiments carried out at the beamline BM08-GILDA of ESRF allowed a study of the structural modifications taking place in a Pt/ceria-zirconia catalyst while the CO oxidation reaction was in progress. The capillary tube in which the sample is stored acts effectively as a chemical microreactor that ensures homogeneity of the sample treatments and minimization of diffusion effects. During the flowing of the reactant CO/He mixture, the investigated catalyst undergoes a fast Ce(IV)-Ce(III) partial reduction that involves the release of one O atom for every two reduced Ce cations. Because Ce(III) has a larger ionic radius than Ce(IV), the structural modification p…
The application of headspace gas chromatography coupled to tandem quadrupole mass spectrometry for the analysis of furan in baby food samples.
2015
Abstract Selective methodology employing a tandem quadrupole mass spectrometer coupled to a gas chromatograph with headspace autosampler (HS-GC–MS/MS) was elaborated in this study. Application of the elaborated procedure resulted in a limit of detection of 0.021 μg kg −1 and a limit of quantification of 0.071 μg kg −1 . The mean recoveries during in-house validation ranged from 89% to 109%, and coefficients of variation for repeatability ranged from 4% to 11%. The proposed analytical method was applied for monitoring the furan content of 30 commercial baby food samples available on the Latvian retail market. The level of furan found in these samples varied from 0.45 to 81.9 μg kg −1 , indic…
Isotope shifts and hyperfine structure in the transitions of stable calcium isotopes and calcium-41
1998
Isotope shifts and hyperfine structure in the 4s2 1S0 → 4s4p 1P1 and 4s2 1S0 → 4s4d 1D2 transitions of calcium have been measured with high-precision laser spectroscopy. Calcium atoms in an atomic beam were excited with single-frequency cw dye and titanium sapphire lasers and then photoionized with the 363.8 nm or 514.5 nm line of an argon ion laser. The resulting ions were analyzed and detected with a quadrupole mass spectrometer. Isotope shifts for all stable calcium isotopes and the radionuclide 41Ca have been measured in both transitions. The corresponding field shift and specific mass shift coefficients as well as hyperfine structure constants for the isotopes 41, 43Ca have been derive…
Ultratrace analysis of calcium with high isotopic selectivity by diodelaser resonance ionisation mass spectrometry
1997
A resonance ionisation mass spectrometer for the ultratrace determination of calcium isotopes is presented. It achieves high overall efficiency, ultra-high isotopic abundance sensitivity of more than 1010 and complete suppression of isobars. The system can be used for isotope ratio studies on stable and long-lived trace isotopes with the final goal of radiodating via 41Ca-determination. For the different applications optical one-, two- or three-step resonance excitation and subsequent ionisation is applied using simple and inexpensive diodelasers. Additional mass analysis is accomplished in a commercial quadrupole mass spectrometer. The experimental set-up and first results on synthetical a…
Isotope shifts and hyperfine structure in the transitions of gadolinium
2000
High-resolution resonance ionization mass spectrometry has been used to measure isotope shifts and hyperfine structure in all (J = 2-6) and the transitions of gadolinium (Gd I). Gadolinium atoms in an atomic beam were excited with a tunable single-frequency laser in the wavelength range of 422-429 nm. Resonant excitation was followed by photoionization with the 363.8 nm line of an argon ion laser and resulting ions were mass separated and detected with a quadrupole mass spectrometer. Isotope shifts for all stable gadolinium isotopes in these transitions have been measured for the first time. Additionally, the hyperfine structure constants of the upper states have been derived for the isotop…
Lead speciation in rainwater samples by modified fused silica capillaries coupled to a direct injection nebulizer (DIN) for sample introduction in IC…
2001
Lead speciation using modified silica capillaries for the introduction of liquid samples to a direct injection nebulizer of an inductively coupled plasma quadrupole mass spectrometer is described and demonstrated. The fused silica capillaries were coated by covalently bonding a cation exchange active organic molecule to the activated capillary surface. The best results were obtained by introducing a bifunctional reagent in a prior step. In this case, a silane reagent was chosen which acted as a methacrylic acid group for further binding. The influence of the chemical modification of the surface of the sample capillary of the DIN on the selective retention of inorganic lead (Pb2+) and trieth…
A compact apparatus for mass selective resonance ionization spectroscopy in a buffer gas cell
1997
Abstract An ultra-sensitive laser spectroscopic method for the investigation of transuranium nuclides has been developed based on resonance ionization in an argon buffer gas cell. This method has been combined with ion-guide extraction and mass selective direct detection of the resonantly ionized atoms. Using argon as a buffer gas, recoils of fusion reactions can be thermalized even at low pressure. The differential pumping system consists of only one roots pump and two turbo molecular pumps. The set-up has been tested with 243 Am evaporated from a filament located inside the optical gas cell. Resonance ionization is performed using a two-step excitation with an excimer-dye-laser combinatio…